Title :
Initial time-varying flow in the smooth-bore magnetron
Author_Institution :
Lanchester Polytechnic, Department of Electrical Engineering, Coventry, UK
fDate :
7/1/1974 12:00:00 AM
Abstract :
A computer program has been written to study the flow pattern at the switching on of a 2-dimensional smooth-bore magnetron. Time-variation and multistream flow are allowed. The results suggest that a simple single-stream flow cannot be established, but that either a double-stream or a multistream flow is established.
Keywords :
electronics applications of computers; magnetrons; anomalous current; computer program; double stream flow; electronics applications of computers; initial time varying flow; multistream flow; single stream flow; smooth bore magnetron;
Journal_Title :
Electrical Engineers, Proceedings of the Institution of