Title : 
Impulse-voltage breakdown of cold pressurised helium
         
        
        
            Author_Institution : 
CEGB, Central Electricity Research Laboratories, Kelvin Laboratories, Leatherhead, UK
         
        
        
        
        
            fDate : 
2/1/1974 12:00:00 AM
         
        
        
        
            Abstract : 
Experiments on impulse breakdowns between uniform-field electrodes in helium are described. The breakdown fields of gaps from 1.27 to 6.35 mm are reported for helium conditions varying from 4.5 to 10 K and 0.395 to 0.82 MPa, corresponding to a density range from 25 to 140 kg m¿3. Comparisons with published direct-voltage breakdowns are made and the mechanisms discussed.
         
        
            Keywords : 
cable insulation; electric breakdown of gases; helium; cable; cold pressurised helium; impulse voltage breakdown;
         
        
        
            Journal_Title : 
Electrical Engineers, Proceedings of the Institution of
         
        
        
        
        
            DOI : 
10.1049/piee.1974.0028