• DocumentCode
    1436909
  • Title

    A Comprehensive Model to Predict the Timing Resolution of SiPM-Based Scintillation Detectors: Theory and Experimental Validation

  • Author

    Seifert, Stefan ; Van Dam, Herman T. ; Vinke, Ruud ; Dendooven, Peter ; Löhner, Herbert ; Beekman, Freek J. ; Schaart, Dennis R.

  • Author_Institution
    Delft Univ. of Technol., Delft, Netherlands
  • Volume
    59
  • Issue
    1
  • fYear
    2012
  • Firstpage
    190
  • Lastpage
    204
  • Abstract
    Silicon photomultipliers (SiPMs) are expected to replace photomultiplier tubes (PMTs) in several applications that require scintillation detectors with excellent timing resolution, such as time-of-flight positron emission tomography (TOF-PET). However, the theory about the timing resolution of SiPM-based detectors is not yet fully understood. Here we propose a comprehensive statistical model to predict the timing resolution of SiPM-based scintillation detectors. It incorporates the relevant SiPM-related parameters (viz. the single cell electronic response, the single cell gain, the charge carrier transit time spread, and crosstalk) as well as the scintillation pulse rise and decay times, light yield, and energy resolution. It is shown that the proposed model reduces to the well-established Hyman model for timing with PMTs if the number of primary triggers (photoelectrons in case of a PMT) is Poisson distributed and crosstalk and electronic noise are negligible. The model predictions are validated by measurements of the coincidence resolving times (CRT) for 511 keV photons of two identical detectors as a function of SiPM bias voltage, for two different kinds of scintillators, namely LYSO:Ce and LaBr3:5%Ce. CRTs as low as 138 ps ± 2 ps FWHM for LYSO:Ce and 95 ps ± 3 ps FWHM for LaBr3:5%Ce were obtained, demonstrating the outstanding timing potential of SiPM-based scintillation detectors. These values were found to be in good agreement with the predicted CRTs of 140 ps FWHM and 95 ps FWHM, respectively. Utilizing the proposed model, it can be shown that the CRTs obtained in our experiments are mainly limited by photon statistics while crosstalk, electronic noise and signal bandwidth have relatively little influence.
  • Keywords
    Poisson distribution; crosstalk; photomultipliers; positron emission tomography; semiconductor device models; semiconductor device noise; solid scintillation detectors; Hyman model; LYSO-Ce scintillator; LaBr3-Ce scintillator; Poisson distribution; SiPM based scintillation detectors; SiPM bias voltage; charge carrier transit time spread; coincidence resolving time; electron volt energy 511 keV; negligible crosstalk noise; negligible electronic noise; photon statistics; positron emission tomography; primary trigger number; scintillation decay time; scintillation energy resolution; scintillation light yield; scintillation pulse rise time; silicon photomultipliers; single cell electronic response; single cell gain; statistical model; time of flight PET; timing resolution prediction; Crosstalk; Detectors; Photonics; Predictive models; Probability density function; Shape; Timing; Gamma ray detection; model; multi pixel photon counter (MPPC); nuclear medicine; positron emission tomography (PET); scintillation counters; silicon photomultiplier (SiPM); time of flight (TOF); timing resolution;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2011.2179314
  • Filename
    6144029