DocumentCode
1438529
Title
Air-cored foil-wound inductors
Author
Reeves, R.
Author_Institution
British Gas Corporation, Research & Development Division, Engineering Research Station, Newcastle upon Tyne, UK
Volume
125
Issue
5
fYear
1978
fDate
5/1/1978 12:00:00 AM
Firstpage
460
Lastpage
464
Abstract
The inductance value of a foil-wound inductor is equal to that of a similar wire-wound inductor at low frequencies, but as the frequency rises, the foil inductance decreases by about 10% because of current redistribution across the foil width. A table and a formula for d.c. inductance values are given. The occurrence of a first resonance frequency due to intertum capacitance is explained and an approximate formula stated. Methods of optimising the design of foil inductors are described. Compared with wire inductors, foil coils have considerable a.c. resistance.
Keywords
foils; inductors; air cored foil wound inductors; inductance; interturn capacitance; resonance frequency;
fLanguage
English
Journal_Title
Electrical Engineers, Proceedings of the Institution of
Publisher
iet
ISSN
0020-3270
Type
jour
DOI
10.1049/piee.1978.0111