DocumentCode :
1439635
Title :
Analysis of very-high-resistance grounding in high-voltage longwall power systems
Author :
Novak, Thomas
Author_Institution :
Alabama Univ., Tuscaloosa, AL, USA
Volume :
37
Issue :
1
fYear :
2001
Firstpage :
104
Lastpage :
111
Abstract :
The application of very sensitive ground-fault protection in underground coal mines was demonstrated in the early 1980s for low- and medium-voltage utilization circuits (less than 1 kV), but its commercial application did not occur until the advent of high-voltage utilization circuits on longwalls in the late 1980s. With these high-voltage systems (greater than 1000 V), the Mine Safety and Health Administration initially required a maximum ground-fault resistor current limit of 3.75 A for 4160 V systems and 6.5 A for 2400 V systems in 101-c Petitions for Modification. However, more recent Petitions for Modification have been required to limit maximum ground-fault resistor currents to 1.0 A, or even 0.5 A. Standard practice in other industries generally requires high-resistance grounding to be designed so that the capacitive charging current of the system is less than or equal to the resistor current under a ground-fault condition. The intent of this practice is to prevent the system from developing some of the undesirable characteristics of an ungrounded system, such as overvoltages from inductive-capacitive resonance effects and intermittent ground faults. Shielded cables, which have significantly more capacitance than their unshielded counterparts, are required for high-voltage applications in the mining industry. Thus, with the long cable runs of a high-voltage longwall system, capacitive charging currents may exceed grounding-resistor currents under ground-fault conditions. An analysis of a typical 4160 V longwall power system that utilizes very-high-resistance grounding (grounding-resistor-current limit of 0.5 A) is performed to determine whether or not potential problems exist
Keywords :
cable shielding; capacitance; earthing; mining; power cables; power system faults; power system protection; 4160 V; Mine Safety and Health Administration; Petitions for Modification; capacitance; capacitive charging current; capacitive charging currents; ground-fault conditions; ground-fault resistor currents; high-voltage longwall power systems; high-voltage utilization circuits; sensitive ground-fault protection; shielded cables; underground coal mines; very-high-resistance grounding; Cable shielding; Capacitance; Circuit faults; Grounding; Health and safety; Medium voltage; Protection; Resistors; Resonance; Surges;
fLanguage :
English
Journal_Title :
Industry Applications, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-9994
Type :
jour
DOI :
10.1109/28.903132
Filename :
903132
Link To Document :
بازگشت