• DocumentCode
    1441729
  • Title

    Sensed reconnection of induction-motor supplies

  • Author

    Thomason, B. ; Gallagher, P.J. ; Shepherd, W.

  • Author_Institution
    Bradford College, School of Technology & Design, Bradford, UK
  • Volume
    125
  • Issue
    2
  • fYear
    1978
  • fDate
    2/1/1978 12:00:00 AM
  • Firstpage
    125
  • Lastpage
    128
  • Abstract
    The paper indicates how the reconnection of the supply to a running induction motor can be effected in a manner that avoids excessive transient disturbances. An optimum condition is postulated for a matched reconnection and the paper indicates how this selected reclosure can be brought about. Typical results obtained by the sensed-switching technique are illustrated for a 3.75 kW (Shp) motor and are compared with results obtained during random switching of the same machine.
  • Keywords
    induction motors; power supplies to apparatus; switching; transients; induction motor; matched reconnection; sensed switching technique; transient disturbances;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineers, Proceedings of the Institution of
  • Publisher
    iet
  • ISSN
    0020-3270
  • Type

    jour

  • DOI
    10.1049/piee.1978.0034
  • Filename
    5253291