• DocumentCode
    1442282
  • Title

    High-frequency AC-DC differences of NML single-junction thermal voltage converters

  • Author

    Budovsky, Ilya ; Inglis, Barry D.

  • Author_Institution
    Nat. Meas. Lab., CSIRO, Lindfield, NSW, Australia
  • Volume
    50
  • Issue
    1
  • fYear
    2001
  • fDate
    2/1/2001 12:00:00 AM
  • Firstpage
    101
  • Lastpage
    105
  • Abstract
    Frequency-dependent AC-DC transfer differences of a new set of single-junction thermal converters that serve at NML as primary standards for AC-DC transfer have been determined. The new determination has led to a reduction of the standard measurement uncertainty from 30 μV/V to less than 10 μV/V at frequencies up to 1 MHz
  • Keywords
    convertors; measurement uncertainty; skin effect; transfer standards; voltage measurement; AC voltage measurement; frequency-dependent AC-DC transfer differences; high-frequency AC-DC differences; primary standards; series inductance; shunting admittance; single-junction thermal voltage converters; skin effect; standard measurement uncertainty; stray capacitance loss; Analog-digital conversion; Current measurement; Frequency; Power measurement; Resistors; Skin effect; Tellurium; Thermal resistance; Uncertainty; Voltage;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/19.903885
  • Filename
    903885