DocumentCode
1443626
Title
A method for correlating duty-cycle tests on solenoids
Author
Ryan, J. E.
Author_Institution
General Electric Company, Schenectady, N. Y.
Volume
62
Issue
9
fYear
1943
Firstpage
579
Lastpage
581
Abstract
A SOLENOID is customarily rated in terms of the minimum pull exerted at any point within its rated stroke when a certain fraction of its nominal voltage is impressed on the coil. Furthermore, when full nominal voltage is applied continuously, the temperature rise of the coil must not exceed a certain value, depending on the class of insulation used and the maximum ambient temperature.
Keywords
Coils; Correlation; Equations; Heating; Iron; Solenoids; Temperature dependence;