DocumentCode
1444432
Title
Turn ratio of the capacitor motor
Author
Mcfarland, Thomas C.
Author_Institution
University of California, Berkeley, Calif.
Volume
62
Issue
12
fYear
1943
Firstpage
892
Lastpage
898
Abstract
IN a previous paper1 the basic equations for the stator and rotor-winding currents of the capacitor motor were established in terms of certain coefficients which were functions of the fundamental constants of the machine. Application of these relations to establish the current loci was made to typical design data taken from earlier papers by Morrill,2 and Puchstein and Lloyd,3 based on a single value of the ratio of auxiliary-winding turns to main-winding turns. It is the purpose of this paper to extend the investigation to determine the effects upon current loci, and upon certain performance characteristics, of changing the turn ratio.
Keywords
Capacitance; Capacitors; Copper; Equations; Friction; Machinery; Windings;
fLanguage
English
Journal_Title
Electrical Engineering
Publisher
ieee
ISSN
0095-9197
Type
jour
DOI
10.1109/EE.1943.6436063
Filename
6436063