Title : 
Thyristor chopper control and the introduction of harmonic currents into track circuits. Practical tests
         
        
            Author : 
Duck, E.W. ; Lawrence, L.S. ; Lowe, T.J.
         
        
            Author_Institution : 
London Transport, Acton Works, London, UK
         
        
        
        
        
            fDate : 
6/1/1976 12:00:00 AM
         
        
        
        
            Abstract : 
The paper covers the practical measurements made, by London Transport, on the levels of induced current in track circuits produced by conventional and thyristor-(chopper-) type traction equipment on their 4th-rail traction supply system. The method of measurement, the subsequent method of analysis and the implications of the results are described and discussed.
         
        
            Keywords : 
choppers (circuits); electric current measurement; harmonic analysis; thyristor applications; traction; harmonic currents; induced current; measurements; practical tests; thyristor chopper control; track circuits; traction supply system;
         
        
        
            Journal_Title : 
Electrical Engineers, Proceedings of the Institution of
         
        
        
        
        
            DOI : 
10.1049/piee.1976.0119