DocumentCode :
1446028
Title :
Permanent-magnet behaviour under `open-circuit¿ conditions
Author :
Ashen, R.A.
Author_Institution :
Imperial College of Science & Technology, Department of Electrical Engineering, London, UK
Volume :
125
Issue :
12
fYear :
1978
fDate :
12/1/1978 12:00:00 AM
Firstpage :
1410
Lastpage :
1414
Abstract :
In general, the determination of the performance of permanent magnets in free air is a complex problem. Certain, clearly-stated assumptions having been made, an analytical solution for the open-circuit, cylindrical bar magnet is presented, this based on the solution of a partial differential equation for the magnetic scalar-potential distribution within the magnet itself. Rationalised characteristics are presented to enable the minimum axial-flux density within a magnet of given proportions to be determined from a knowledge of the magnet material´s relative permeability and operating characteristic. Hence, an indication may be obtained as to the advisability of leaving the material unkeepered in air. A theoretical characteristic is compared with some preliminary experimental results obtained using a flexible, bonded-ferrite permanent-magnet material.
Keywords :
partial differential equations; permanent magnets; axial flux density; cylindrical bar magnet; open circuit permanent magnet; partial differential equation; relative permeability;
fLanguage :
English
Journal_Title :
Electrical Engineers, Proceedings of the Institution of
Publisher :
iet
ISSN :
0020-3270
Type :
jour
DOI :
10.1049/piee.1978.0298