DocumentCode
1446440
Title
Temperature-aging tests on class-a-insulated fractional-horsepower motor stators
Author
Scott, J. A. ; Thompson, B. H.
Author_Institution
General Electric Company, Schenectady, N. Y.
Volume
61
Issue
7
fYear
1942
fDate
7/1/1942 12:00:00 AM
Firstpage
499
Lastpage
501
Abstract
Temperature-aging data are presented on class-A-insulated fractional-horsepower motor stators, determined at 200, 160, and 135 degrees centigrade. Of particular interest is the relative aging time to failure at the different temperatures and the resultant temperature-aging curve. This curve shows a slope of 10 to 15 degrees centigrade increase in temperature to halve the aging time to failure in the temperature range covered, 135 to 200 degrees centigrade.
Keywords
Aging; IEEE transactions; Induction motors; Insulation; Stators; Temperature distribution;
fLanguage
English
Journal_Title
Electrical Engineering