• DocumentCode
    1446440
  • Title

    Temperature-aging tests on class-a-insulated fractional-horsepower motor stators

  • Author

    Scott, J. A. ; Thompson, B. H.

  • Author_Institution
    General Electric Company, Schenectady, N. Y.
  • Volume
    61
  • Issue
    7
  • fYear
    1942
  • fDate
    7/1/1942 12:00:00 AM
  • Firstpage
    499
  • Lastpage
    501
  • Abstract
    Temperature-aging data are presented on class-A-insulated fractional-horsepower motor stators, determined at 200, 160, and 135 degrees centigrade. Of particular interest is the relative aging time to failure at the different temperatures and the resultant temperature-aging curve. This curve shows a slope of 10 to 15 degrees centigrade increase in temperature to halve the aging time to failure in the temperature range covered, 135 to 200 degrees centigrade.
  • Keywords
    Aging; IEEE transactions; Induction motors; Insulation; Stators; Temperature distribution;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineering
  • Publisher
    ieee
  • ISSN
    0095-9197
  • Type

    jour

  • DOI
    10.1109/EE.1942.6436421
  • Filename
    6436421