DocumentCode :
1446440
Title :
Temperature-aging tests on class-a-insulated fractional-horsepower motor stators
Author :
Scott, J. A. ; Thompson, B. H.
Author_Institution :
General Electric Company, Schenectady, N. Y.
Volume :
61
Issue :
7
fYear :
1942
fDate :
7/1/1942 12:00:00 AM
Firstpage :
499
Lastpage :
501
Abstract :
Temperature-aging data are presented on class-A-insulated fractional-horsepower motor stators, determined at 200, 160, and 135 degrees centigrade. Of particular interest is the relative aging time to failure at the different temperatures and the resultant temperature-aging curve. This curve shows a slope of 10 to 15 degrees centigrade increase in temperature to halve the aging time to failure in the temperature range covered, 135 to 200 degrees centigrade.
Keywords :
Aging; IEEE transactions; Induction motors; Insulation; Stators; Temperature distribution;
fLanguage :
English
Journal_Title :
Electrical Engineering
Publisher :
ieee
ISSN :
0095-9197
Type :
jour
DOI :
10.1109/EE.1942.6436421