• DocumentCode
    1446720
  • Title

    Analytical treatment for establishing load-cycle ratings of ignitrons

  • Author

    Marshall, D. E. ; Arnott, E. G. F.

  • Author_Institution
    Westinghouse Electric and Manufacturing Company, both in Bloom-field, N. J.
  • Volume
    61
  • Issue
    8
  • fYear
    1942
  • Firstpage
    545
  • Lastpage
    548
  • Abstract
    THE ignitron offers unique possibilities as a control element for high instantaneous alternating demand currents. The demand current is limited only by the capacity of the ionized vapor to conduct the current from the mercury pool to the anode and by probability of arc back, which increases as the peak current conducted by the tube increases. The design of ignitron tubes is a compromise between these two factors. Design for low arc-back rate usually results in anode baffles and shields which tend to increase the deionizing properties of the tube and thus decrease the peak current-carrying capacity.
  • Keywords
    Accuracy; Cooling; Electron tubes; Equations; Heating; Mathematical model; Metals;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineering
  • Publisher
    ieee
  • ISSN
    0095-9197
  • Type

    jour

  • DOI
    10.1109/EE.1942.6436467
  • Filename
    6436467