DocumentCode
1447009
Title
Tailoring Cleanroom for industrial use
Author
Oshana, Robert S.
Author_Institution
Raytheon Syst. Co., Dallas, TX, USA
Volume
15
Issue
6
fYear
1998
Firstpage
46
Lastpage
55
Abstract
In a pilot process improvement program to move from CMM level 3 to level 5, a Raytheon group working on real-time embedded software decided to focus on Cleanroom software engineering technology. The article shares the group´s encouraging lessons learned from tailoring Cleanroom to their specific needs. The author provides evidence to support their claims of success, but cautions readers who want to employ the same approach to their own organizations because concerns, issues, and barriers do exist
Keywords
embedded systems; formal specification; software process improvement; CMM level 3; CMM level 5; Cleanroom software engineering technology; Raytheon group; process improvement program; real-time embedded software; Certification; Companies; Costs; Predictive models; Productivity; Programming; Software engineering; Software quality; Software systems; Software testing;
fLanguage
English
Journal_Title
Software, IEEE
Publisher
ieee
ISSN
0740-7459
Type
jour
DOI
10.1109/52.730840
Filename
730840
Link To Document