Effects of Dielectric Values of Human Body on Specific Absorption Rate Following 430, 800, and 1200 MHz RF Exposure to Ingestible Wireless Device
Author
Xu, L.S. ; Meng, Max Q -H ; Hu, Chao
Author_Institution
Chinese Univ. of Hong Kong, Shatin, China
Volume
14
Issue
1
fYear
2010
Firstpage
52
Lastpage
59
Abstract
In order to assess the compliance of ingestible wireless device (IWD) within safety guidelines, the SAR, and near fields of IWD in two realistic human body models, whose dielectric values are increased from the original by ??10% and ?? 20% are studied using the finite-difference time-domain method. The radiation characteristics of the IWD in the human body models with changed and unchanged dielectric values are compared. Simulations are carried out at 13 scenarios where the IWD is placed at center positions of abdomens in the two models at the operation frequency of 430, 800, and 1200 MHz, respectively. Results show that variation of radiation intensity near the surface of abdomen is around 2.5, 2.6, and 3.5 dB within 20% variation of dielectric values corresponding to the frequency of 430, 800, and 1200 MHz, respectively. Electric fields in the anterior of the human body models are higher than those in the posterior for all scenarios. SAR values increase with the increase of conductivities of human body tissues, and usually decrease with the increase of relative permittivities of human body tissues. The effect of the dielectric values of human body on SAR is orientation-, human-body-, and frequency-dependent. A variation up to 20% in conductivities and relative permittivities alone or simultaneously always causes a SAR variation less than 10%, 20%, and 30% at the frequency of 430, 800, and 1200 MHz, respectively. As far as the compliance of safety was concerned, the IWD was safe to be used at the input power less than 12.6, 9.3, and 8.4 mW, according to the IEEE safety standards at the frequency of 430, 800, and 1200 MHz, respectively.
Keywords
biological effects of fields; biological tissues; finite difference time-domain analysis; permittivity; abdomen; dielectric values; electric field; finite difference time domain method; frequency 1200 MHz; frequency 430 MHz; frequency 800 MHz; human body tissues; ingestible wireless device; permittivity; specific absorption rate; Dielectric value; SAR; finite-difference time domain (FDTD); ingestible wireless device (IWD); radiation characteristics; Absorption; Capsule Endoscopy; Computer Simulation; Electromagnetic Fields; Female; Humans; Intestine, Small; Male; Models, Biological; Radio Waves;
fLanguage
English
Journal_Title
Information Technology in Biomedicine, IEEE Transactions on
Publisher
ieee
ISSN
1089-7771
Type
jour
DOI
10.1109/TITB.2009.2029853
Filename
5256151
Link To Document