DocumentCode
1447856
Title
New snubber circuit with passive energy recovery for power inverters
Author
He, X. ; Williams, B.W. ; Finney, S.J. ; Qian, Z. ; Green, T.C.
Author_Institution
Dept. of Electr. Eng., Zhejiang Univ., Hangzhou, China
Volume
143
Issue
5
fYear
1996
fDate
9/1/1996 12:00:00 AM
Firstpage
403
Lastpage
408
Abstract
The paper proposes a new passive circuit for partial snubber-energy recovery in GTO thyristor high-power voltage-source inverters. The analysis and simulations show that the proposed bridge-leg snubber circuit can recover greater than sixty five per cent of the total snubber energy, as well as the freewheel diode reverse recovery energy. This energy is recovered back to the DC supply through a closely coupled transformer, without any active or associated control circuitry. This circuit, being simple, is particularly for use in GTO thyristor high-power. Design equations, simulations and experimental results are given
Keywords
DC-AC power convertors; bridge circuits; invertors; snubbers; thyristor convertors; DC supply; GTO thyristor; VSI; bridge-leg snubber circuit; freewheel diode; passive energy recovery; reverse recovery energy; snubber circuit;
fLanguage
English
Journal_Title
Electric Power Applications, IEE Proceedings -
Publisher
iet
ISSN
1350-2352
Type
jour
DOI
10.1049/ip-epa:19960518
Filename
543634