DocumentCode :
1450426
Title :
Effect of Stress Due to Plastic Package Moisture Absorption in Hall Sensors
Author :
Cesaretti, J.M. ; Taylor, W.P. ; Monreal, G. ; Brand, O.
Author_Institution :
Allegro Microsyst., Inc., Worcester, MA, USA
Volume :
45
Issue :
10
fYear :
2009
Firstpage :
4482
Lastpage :
4485
Abstract :
Commercial magnetic sensors based on the Hall effect are usually encapsulated in non-hermetic plastic packages. These plastic packages are known to swell in high humidity conditions due to moisture absorption. This swelling will modify the stress seen by the Hall sensor, causing the Hall sensitivity to be altered due to the piezo-Hall effect. The sensitivity drift, which is random in nature, may become the long-term stability limiting factor in high-end sensors. The objective of this work is to characterize in depth the sensitivity change due to moisture absorption and to review and implement two Hall sensitivity compensation methods.
Keywords :
Hall effect transducers; absorption; compensation; magnetic sensors; moisture; plastics; Hall sensitivity compensation methods; Hall sensors; commercial magnetic sensors; high humidity conditions; piezo-Hall effect; plastic package moisture absorption; sensitivity drift; stability limiting factor; stress effect; Compensation; Hall effect; Piezo-Hall; moisture absorption; stress;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/TMAG.2009.2025668
Filename :
5257195
Link To Document :
بازگشت