• DocumentCode
    1453997
  • Title

    Post-processing enhancement of reverberation-noise suppression in dual-frequency SURF imaging

  • Author

    Näsholm, Sven Peter ; Hansen, Rune ; Angelsen, Bjørn A J

  • Author_Institution
    Dept. of Circulation & Imaging, Norwegian Univ. of Sci. & Technol., Trondheim, Norway
  • Volume
    58
  • Issue
    2
  • fYear
    2011
  • fDate
    2/1/2011 12:00:00 AM
  • Firstpage
    338
  • Lastpage
    348
  • Abstract
    A post-processing adjustment technique to enhance dual-frequency second-order ultrasound field (SURF) reverberation-noise suppression imaging in medical ultrasound is analyzed. Two variant methods are investigated through numerical simulations. They both solely involve post-processing of the propagated high-frequency (HF) imaging wave fields, which in real-time imaging corresponds to post-processing of the beamformed receive radio-frequency signals. Hence, the transmit pulse complexes are the same as for the previously published SURF reverberation-suppression imaging method. The adjustment technique is tested on simulated data from propagation of SURF pulse complexes consisting of a 3.5-MHz HF imaging pulse added to a 0.5-MHz low-frequency sound-speed manipulation pulse. Imaging transmit beams are constructed with and without adjustment. The post-processing involves filtering, e.g., by a time-shift, to equalize the two SURF HF pulses at a chosen depth. This depth is typically chosen to coincide with the depth where the first scattering or reflection occurs for the reverberation noise one intends to suppress. The beams realized with post-processing show energy decrease at the chosen depth, especially for shallow depths where, in a medical imaging situation, a body-wall is often located. This indicates that the post-processing may further enhance the reverberation- suppression abilities of SURF imaging. Moreover, it is shown that the methods might be utilized to reduce the accumulated near-field energy of the SURF transmit-beam relative to its imaging region energy. The adjustments presented may therefore potentially be utilized to attain a slightly better general suppression of multiple scattering and multiple reflection noise compared with non-adjusted SURF reverberation-suppression imaging.
  • Keywords
    biomedical ultrasonics; interference suppression; medical image processing; reverberation; SURF; dual-frequency SURF imaging; high-frequency imaging; post-processing adjustment; reverberation-noise suppression; second-order ultrasound field; sound-speed manipulation pulse; Apertures; Hafnium; Imaging; Noise; Reverberation; Scattering; Ultrasonic imaging; Algorithms; Artifacts; Computer Simulation; Signal Processing, Computer-Assisted; Transducers; Ultrasonography;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2011.1811
  • Filename
    5716451