Title :
Reliability of 28-volt D-C aircraft distribution systems
Author :
Carlson, K. W. ; Sherrard, E. S.
Author_Institution :
General Electric Company, Schenectady, N. Y.
Abstract :
An analysis of protection of a typical 28-volt d-c distribution system for large multiengine aircraft is presented. Conclusions regarding bus and feeder fault protection and arrangement are included.
Keywords :
Aircraft; Batteries; Circuit faults; Generators; Power cables; Relays; Reliability;
Journal_Title :
Electrical Engineering
DOI :
10.1109/EE.1952.6437649