Title : 
Interlaminar insulation test for stators
         
        
            Author : 
Tomlinson, H. R.
         
        
            Author_Institution : 
New England Power Service Company, Boston, Mass.
         
        
        
        
        
        
        
            Abstract : 
IT IS OFTEN DESIRABLE to test the effectiveness of the interlaminar insulation in a generator stator. Iron damage may be sustained as a consequence of mechanical abrasion or arc burning during a winding insulation failure. A simple flux test can be made to determine if the interlaminar insulation has been impaired within a damaged area which might develop into a hot spot when the machine is restored to service.
         
        
            Keywords : 
Coils; Insulation; Iron; Magnetic flux; Saturation magnetization; Stators; Windings;
         
        
        
            Journal_Title : 
Electrical Engineering
         
        
        
        
        
            DOI : 
10.1109/EE.1952.6437791