DocumentCode
1454886
Title
D-G motor losses with rectifier operation
Author
Reiter, C. R. ; Ammerman, C. R.
Author_Institution
Shell Oil Company, Elk City, Okla.
Volume
71
Issue
11
fYear
1952
Firstpage
1025
Lastpage
1025
Abstract
THE USE OF grid-controlled rectifiers for the supply of controlled power to d-c machinery has raised the problem of the increased losses in motors used in this way. The output of a grid-controlled rectifier has a large ripple voltage, the waveform of which varies with the firing delay caused by the grid control. This ripple causes alternating currents to flow in the motor which do not add to the rotational power produced but which cause additional copper loss. In addition, another component of flux is created in the magnetic circuit which causes additional hysteresis and eddy current losses.
Keywords
Copper; DC motors; Delay; Hysteresis motors; Iron; Rectifiers;
fLanguage
English
Journal_Title
Electrical Engineering
Publisher
ieee
ISSN
0095-9197
Type
jour
DOI
10.1109/EE.1952.6437792
Filename
6437792
Link To Document