Effect of humidity on the power frequency flashover voltage of insulators and gaps at varying temperature conditions
Author :
Venkataraman, C.S. ; Prabhakar, B.R. ; Nandagopal, M.R.
Volume :
14
Issue :
6
fYear :
1976
Firstpage :
237
Lastpage :
242
Abstract :
The work reported in the paper is a part of data collection on the effect of humidity on the flashover voltage of insulators and gaps at different temperature conditions. In the present investigation, studies were made at two constant temperatures of 30°C and 37°C. The corresponding humidity variations were 11 gms/m3 to 25 gms/m3 and 16 gms/m3 to 30 gms/m3 respectively. Insulators and air gaps were subjected to a power frequency voltage, under the above conditions. The results are presented through graphs.
Keywords :
flashover; insulators; spark gaps; flashover voltage; humidity effect; insulators; spark gap; varying temperature conditions;
fLanguage :
English
Journal_Title :
India, IEE-IERE Proceedings -
Publisher :
iet
ISSN :
0018-9146
Type :
jour
DOI :
10.1049/iipi.1976.0073