Threshold calculation for segmented attenuation correction in PET with histogram fitting
Author
Bilger, K. ; Kupferschläger, J. ; Müller-Schauenburg, W. ; Nusslin, F. ; Bares, R.
Author_Institution
Dept. of Nucl. Med., Tubingen Univ., Germany
Volume
48
Issue
1
fYear
2001
fDate
2/1/2001 12:00:00 AM
Firstpage
43
Lastpage
50
Abstract
Various techniques for segmented attenuation correction (SAC) have been shown to be capable of reducing transmission scan time significantly and performing accurate image quantification. The majority of well established methods are based on analyzing attenuation histograms to classify the main tissue components, which are lung and soft tissue. Methods using statistical approaches, i.e. class variances, to separate two clusters of a measured attenuation map have been shown to perform accurate attenuation correction at a scan lime within a range of 2-3 min, but may fail due to peak deformations, which occur when the transmission scan time is further reduced. The authors implemented a new method for segmented attenuation correction with the aim of minimizing the transmission scan time and increasing the robustness for extremely short scan times using a coincidence transmission device. The implemented histogram fitting segmentation (HFS) allows accurate threshold calculation without assuming normally distributed peaks in the histogram, by adapting a suitable function to the soft tissue peak. The algorithm uses an estimated lung position (ELP) for patient contour finding and lung segmentation. Iterative reconstruction is used to generate the transmission images
Keywords
gamma-ray absorption; image reconstruction; image segmentation; iterative methods; lung; medical image processing; positron emission tomography; 2 to 3 min; PET; accurate threshold calculation; coincidence transmission device; estimated lung position; histogram fitting; iterative reconstruction; lung segmentation; medical diagnostic imaging; normally distributed peaks; nuclear medicine; patient contour finding; segmented attenuation correction; threshold calculation; transmission images generation; transmission scan time reduction; Attenuation measurement; Biological tissues; Histograms; Image segmentation; Iterative algorithms; Lungs; Performance evaluation; Positron emission tomography; Robustness; Time measurement;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/23.910831
Filename
910831
Link To Document