• DocumentCode
    1455842
  • Title

    A method of compensation of the frequency dependent systematic error of the time-division watt-converter

  • Author

    Jovanovic, Ljubisa D.

  • Author_Institution
    Inst. Mihajlo Pupin, Beograd, Yugoslavia
  • Volume
    46
  • Issue
    2
  • fYear
    1997
  • fDate
    4/1/1997 12:00:00 AM
  • Firstpage
    416
  • Lastpage
    419
  • Abstract
    The paper presents a method for the compensation of the frequency dependent systematic error of the Time-Division Multiplier of the Goldberg type (TDM). The method Is based on using the additional correcting circuits on the TDM inputs whereby theoretically perfect compensation can be achieved under conditions derived analytically in this paper. Applying this method it is possible to compensate the systematic error in a relatively large range of input signal frequencies even in the cases when both input signals are not limited to one single frequency but have harmonics. In order to verify the performances of the method an adequate, high precision TDM based watt-converter has been developed. Theoretically and experimentally it is shown that the high performances (accuracy better than ±100×10-6) of the multiplier can be obtained in the input frequency range from 50 Hz to 20 kHz even in the case when the conversion frequency is only 10 times the input signal frequency
  • Keywords
    error compensation; measurement errors; power measurement; wattmeters; 50 Hz to 20 kHz; compensation; conversion frequency; frequency dependent systematic error; input signal frequencies; time-division watt-converter; Circuits; Distortion; Frequency conversion; Frequency dependence; Frequency measurement; Helium; Power measurement; Time division multiplexing; Voltage; Wattmeters;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/19.571870
  • Filename
    571870