• DocumentCode
    1456773
  • Title

    Energy stress on transmission line arresters considering the total lightning charge distribution

  • Author

    Stenström, L. ; Lundquist, J.

  • Author_Institution
    ABB Switchgear, Ludvika, Sweden
  • Volume
    14
  • Issue
    1
  • fYear
    1999
  • fDate
    1/1/1999 12:00:00 AM
  • Firstpage
    148
  • Lastpage
    151
  • Abstract
    Transmission line arresters may be subjected to high energy stresses caused by lightning. Calculations of energy stresses were carried out for a typical line arrester installation. Three line configurations with different degrees of shielding efficiency were used for the study. The primary statistical parameter was the charge of the flash, including multiple strokes. The effect of stroke current magnitude was also investigated. The calculated results were compared with energy stresses in standardized tests on surge arresters
  • Keywords
    arresters; electric charge; lightning; power overhead lines; power transmission protection; shielding; energy stress; flash charge; line configurations; multiple strokes; shielding efficiency; standardized tests; statistical parameter; stroke current magnitude; surge arresters; total lightning charge distribution; transmission line arresters; Arresters; Grounding; Lightning; Poles and towers; Power transmission lines; Stress; Substations; Surge protection; Transmission lines; Wires;
  • fLanguage
    English
  • Journal_Title
    Power Delivery, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8977
  • Type

    jour

  • DOI
    10.1109/61.736706
  • Filename
    736706