DocumentCode
1459401
Title
Coherent scatter implementation for SimSET
Author
Kaplan, M.S. ; Harrison, R.L. ; Vannoy, S.D.
Author_Institution
Washington Univ., Seattle, WA, USA
Volume
45
Issue
6
fYear
1998
fDate
12/1/1998 12:00:00 AM
Firstpage
3064
Lastpage
3068
Abstract
At 140 keV, 3% of photon scatter interactions in human tissues are coherent scatter; at Tl-201 emission energies, this fraction increases to approximately 7%. However, since coherent scatter at these energies is sharply forward-peaked, it is often the dominant scatter interaction at small angles. SimSET (Simulation System for Emission Tomography), which previously modeled only photoelectric absorption and Compton scatter, has been extended to include coherent scatter. The current implementation uses form factor and anomalous scattering amplitude data from the Livermore Evaluated Photon Data Library. Interaction probability and angular distribution tables for several human tissues and common detector materials were calculated using the independent atoms approximation and human-tissue composition data from the ICRP Reference Man. These data were also used to generate new tables for photoelectric absorption and Compton scatter, significantly improving the accuracy of SimSET and extending its photon tracking capability to lower photon energy (from 50 keV to 1 keV). The form, content, and structure of the tables were carefully designed for efficient data storage, access, and use by the software. The derived data tables and implementation of coherent scatter were validated by comparing simulation results to published differential cross-section data
Keywords
Compton effect; digital simulation; emission tomography; gamma-ray scattering; medical image processing; photoelectricity; software packages; 140 keV; 50 to 1 keV; Compton scatter; ICRP Reference Man; Livermore Evaluated Photon Data Library; SimSET; angular distribution tables; anomalous scattering amplitude data; coherent scatter implementation; common detector materials; differential cross-section data; form factor; human tissues; human-tissue composition data; interaction probability; medical diagnostic imaging; nuclear medicine; photoelectric absorption; Absorption; Biological materials; Composite materials; Detectors; Electromagnetic scattering; Humans; Libraries; Particle scattering; Probability; Tomography;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/23.737665
Filename
737665
Link To Document