Title : 
Long term accelerated aging tests on distribution cables under wet conditions
         
        
            Author : 
Bartnikas, R. ; Densley, R.J. ; Eichhorn, R.M.
         
        
            Author_Institution : 
Inst. de Recherche, Hydro-Quebec, Varennes, Que., Canada
         
        
        
        
        
            fDate : 
10/1/1996 12:00:00 AM
         
        
        
        
            Abstract : 
Two accelerated aging test procedures are proposed for use on solid dielectric extruded distribution cables under wet conditions. One test method is a fixed time duration test in which the degree of cable specimen aging is assessed in terms of breakdown tests, while the other test method is a time to breakdown test in which the cable specimens are voltage stressed until failure ensues
         
        
            Keywords : 
XLPE insulation; ageing; distribution networks; electric breakdown; insulation testing; life testing; power cable insulation; power cable testing; XLPE cables; accelerated aging tests; breakdown tests; cable specimen aging; distribution cables; fixed time duration test; solid dielectric extruded distribution cables; voltage stressed cables specimens; wet conditions; Accelerated aging; Breakdown voltage; Cables; Conductors; Dielectrics; Electric breakdown; Life estimation; Solids; Stress; System testing;
         
        
        
            Journal_Title : 
Power Delivery, IEEE Transactions on