DocumentCode
1461528
Title
Low magnetic field measurement with a reversed-field electron-spin-resonance magnetometer
Author
Shirai, Terumitsu
Author_Institution
Calibration Lab., Japan Electr. Meters Inspection Corp., Tokyo, Japan
Volume
36
Issue
6
fYear
2000
fDate
11/1/2000 12:00:00 AM
Firstpage
3953
Lastpage
3956
Abstract
An effective method of measuring low magnetic fields is presented. In this method, the magnetic field direction is reversed periodically so that the effects of external magnetic fields, such as the earth´s magnetism, are removed. The usefulness of the method is investigated by using a split coil magnetic field source and an electron-spin-resonance magnetometer. A magnetic field of 10 mT can be measured with an uncertainty of less than 0.2 μT, i.e., 20 ppm
Keywords
EPR spectrometers; magnetic field measurement; magnetometers; measurement uncertainty; 10 mT; external magnetic field effect removal; low magnetic field measurement; magnetic field direction periodic reversal; measurement uncertainty; reversed-field electron-spin-resonance magnetometer; split coil magnetic field source; Coils; Electric variables measurement; Inspection; Magnetic field measurement; Magnetic resonance; Magnetic shielding; Magnetometers; Nuclear magnetic resonance; Paramagnetic resonance; Watthour meters;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/20.914345