Title :
Test results of an inner-cooled generator
Author :
Brenner, W. C. ; Heller, P. R.
Author_Institution :
Westinghouse Electric Corporation, East Pittsburgh, Pa.
fDate :
7/1/1954 12:00:00 AM
Abstract :
The specific electrical tests conducted are discussed together with the results obtained. These shop tests, which agreed closely with the calculated performance, demonstrated the practicability of applying the improved cooling technique to large turbine generators.
Keywords :
Coils; Copper; Detectors; Electrical resistance measurement; Generators; Hydrogen; Temperature measurement;
Journal_Title :
Electrical Engineering
DOI :
10.1109/EE.1954.6438878