DocumentCode :
1463263
Title :
The evaluation of oxide-cathode quality by shot-noise tests
Author :
Sebestyen, L.G.
Volume :
21
Issue :
5
fYear :
1961
fDate :
5/1/1961 12:00:00 AM
Firstpage :
463
Lastpage :
467
Abstract :
As is well known, the space-charge reduced shot noise of a triode can be used as a measure of the cathode emissivity. A simple test equipment is described and results of measurements are discussed. The noise tests seem to be more sensitive than other methods without having any detrimental influence on the valve under test. Application for life test is suggested
Keywords :
electron device noise; oxide coated cathodes; triodes;
fLanguage :
English
Journal_Title :
Radio Engineers, Journal of the British Institution of
Publisher :
iet
Type :
jour
DOI :
10.1049/jbire.1961.0059
Filename :
5259777
Link To Document :
بازگشت