Title :
Effect of skew on induction motor fields
Author_Institution :
General Electric Company, Fort Wayne, Ind.
Abstract :
INDUCTION-MOTOR designers have recognized for many years that the skew of the rotor slots with respect to the stator slots produces variations axially across the stack in the net fundamental mmf wave. This variation affects the saturation factors, iron losses, and motor noise.
Keywords :
Associate members; Companies; IEEE transactions; Induction motors; Rotors; Stators; Vectors;
Journal_Title :
Electrical Engineering
DOI :