• DocumentCode
    1466360
  • Title

    Adaptive calibration techniques for time-interleaved ADCs

  • Author

    Ndjountche, T. ; Unbehauen, R.

  • Author_Institution
    Lehrstuhl fur Allgemeine und Theor. Elektrotech., Erlangen-Nurnberg Univ., Germany
  • Volume
    37
  • Issue
    7
  • fYear
    2001
  • fDate
    3/29/2001 12:00:00 AM
  • Firstpage
    412
  • Lastpage
    414
  • Abstract
    At high sampling rates, the resolution of time-interleaved analogue-to-digital converters appears to be limited by the path mismatches, which produce distortions in the output spectrum. Adaptive calibration structures, which can converge in the mean are described. They operate in the background and significantly improve the converter performance
  • Keywords
    analogue-digital conversion; calibration; adaptive calibration techniques; converter performance; output spectrum; path mismatches; sampling rates; time-interleaved ADCs;