DocumentCode
1467206
Title
Identification for long-range predictive control
Author
Shook, D.S. ; Mohtadi, C. ; Shah, S.L.
Author_Institution
Dept. of Chem. Eng., Alberta Univ., Edmonton, Alta., Canada
Volume
138
Issue
1
fYear
1991
fDate
1/1/1991 12:00:00 AM
Firstpage
75
Lastpage
84
Abstract
The current generation of adaptive predictive controllers uses a standard single-step-ahead estimator with multi-step-ahead predictors. In order to obtain satisfactory results in applications, data are bandpass filtered before being used in the estimator. The paper demonstrates that the use of a standard RLS estimator with no data filtering frequently results in unstable closed loops if the parameters are used in a multi-step-ahead control scheme. A multi-step-ahead cost is introduced for parameter estimation as a dual of the control law. It is shown that the method is superior to the standard scheme. The frequency response properties of this estimator indicate that prefiltering of the data prevalent among the reported successful applications of the predictive controller is a natural outcome of this choice of the cost for the estimator scheme. The paper provides some useful guidelines for the choice of order and time constants of these filters
Keywords
filtering and prediction theory; frequency response; parameter estimation; predictive control; RLS estimator; frequency response; identification; long-range; multistep ahead cost; parameter estimation; predictive control; prefiltering;
fLanguage
English
Journal_Title
Control Theory and Applications, IEE Proceedings D
Publisher
iet
ISSN
0143-7054
Type
jour
Filename
61674