An eight-year investigation of lightning currents and preventive lightning protection on a transmission system
Author
Hansson, Erik ; Waldorf, S. K.
Author_Institution
Pennsylvania Water and Power Company, Baltimore, Md.
Volume
63
Issue
5
fYear
1944
fDate
5/1/1944 12:00:00 AM
Firstpage
251
Lastpage
258
Abstract
SOME 10 or 12 years ago effective lightning protection began to be applied to transmission lines, and, about the same time, an inexpensive measuring device (the surge-crest ammeter) was developed.1 On one transmission system this low-cost device has been applied to every structure in entire lines and has produced definite numerical evidence of the performance of the protection provided.
Keywords
Flashover; Lightning; Poles and towers; Resistance; Surge protection; Surges; Wires;
fLanguage
English
Journal_Title
Electrical Engineering
Publisher
ieee
ISSN
0095-9197
Type
jour
DOI
10.1109/EE.1944.6440263