DocumentCode :
1469858
Title :
Parasitic losses in modular permanent-magnet generators
Author :
Spooner, E. ; Williamson, A.C.
Author_Institution :
Sch. of Eng., Durham Univ., UK
Volume :
145
Issue :
6
fYear :
1998
fDate :
11/1/1998 12:00:00 AM
Firstpage :
485
Lastpage :
496
Abstract :
The modular permanent-magnet machine exhibits several new forms of load and no-load loss which could lead to poor efficiency and unacceptable temperature rise if not taken into account in the design. Four such losses are identified. An analytical electromagnetic model of the modular machine and its structure is developed and used to predict the losses. A test rig using modules which are representative of a full scale machine has provided data which validates the model. Use of the model for a typical full-scale design with enlarged modules reveals that the losses can be made acceptably low without special measures to screen the leakage fields which cause the loss
Keywords :
loss measurement; losses; machine testing; machine theory; permanent magnet generators; analytical electromagnetic model; efficiency; full-scale design; leakage fields; losses prediction; modular permanent-magnet generators; parasitic losses; temperature rise; test rig;
fLanguage :
English
Journal_Title :
Electric Power Applications, IEE Proceedings -
Publisher :
iet
ISSN :
1350-2352
Type :
jour
DOI :
10.1049/ip-epa:19982336
Filename :
744040
Link To Document :
بازگشت