• DocumentCode
    1471263
  • Title

    Pseudo-inverse filtering of IVUS images

  • Author

    Young, W.F. ; McLaughlin, S.

  • Author_Institution
    Dept. of Electr. Eng., Edinburgh Univ., UK
  • Volume
    145
  • Issue
    6
  • fYear
    1998
  • fDate
    11/1/1998 12:00:00 AM
  • Firstpage
    321
  • Lastpage
    326
  • Abstract
    The resolution of medical ultrasound systems can be improved using filtering techniques. The authors present a filter for improving the axial resolution that approximates to an inverse filter, but which is less sensitive to noise than a standard inverse filter. The filter is designed in the frequency domain using a sigmoid-based pseudo-inversion technique. This filter is compared with other filtering techniques including a Wiener filter and a matched filter
  • Keywords
    Wiener filters; biomedical ultrasonics; filtering theory; matched filters; medical image processing; IVUS images; Wiener filter; frequency domain; intravascular ultrasound; matched filter; medical ultrasound; pseudo-inverse filtering; sigmoid-based pseudo-inversion; standard inverse filter;
  • fLanguage
    English
  • Journal_Title
    Science, Measurement and Technology, IEE Proceedings -
  • Publisher
    iet
  • ISSN
    1350-2344
  • Type

    jour

  • DOI
    10.1049/ip-smt:19982323
  • Filename
    744424