• DocumentCode
    1471529
  • Title

    A drum boiler model for long term power system dynamic simulation

  • Author

    Flynn, M.E. ; O´Malley, M.J.

  • Author_Institution
    Dept. of Electron. & Electr. Eng., Univ. Coll. Dublin, Ireland
  • Volume
    14
  • Issue
    1
  • fYear
    1999
  • fDate
    2/1/1999 12:00:00 AM
  • Firstpage
    209
  • Lastpage
    217
  • Abstract
    In the event of a power system contingency, the boiler has an important impact on the power output in the long term time frame of minutes to hours. This paper describes a drum boiler model developed from first principles and validated using data from tests carried out on an actual plant. The model can be used for dynamic simulation studies in long time frames, greater than 30 seconds, in particular where assessment of deviations of internal parameters, such as steam pressure, drum level and steam temperature, outside safety limits is essential
  • Keywords
    boilers; parameter estimation; power system simulation; SIMULINK; drum boiler model; drum level; internal parameters deviations assessment; long term power system dynamic simulation; outside safety limits; parameter identification; power output; power system contingency; steam pressure; steam temperature; Analytical models; Boilers; Control system analysis; Integrated circuit modeling; Power generation; Power system dynamics; Power system modeling; Power system protection; Power system simulation; Power system transients;
  • fLanguage
    English
  • Journal_Title
    Power Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8950
  • Type

    jour

  • DOI
    10.1109/59.744528
  • Filename
    744528