DocumentCode :
1471529
Title :
A drum boiler model for long term power system dynamic simulation
Author :
Flynn, M.E. ; O´Malley, M.J.
Author_Institution :
Dept. of Electron. & Electr. Eng., Univ. Coll. Dublin, Ireland
Volume :
14
Issue :
1
fYear :
1999
fDate :
2/1/1999 12:00:00 AM
Firstpage :
209
Lastpage :
217
Abstract :
In the event of a power system contingency, the boiler has an important impact on the power output in the long term time frame of minutes to hours. This paper describes a drum boiler model developed from first principles and validated using data from tests carried out on an actual plant. The model can be used for dynamic simulation studies in long time frames, greater than 30 seconds, in particular where assessment of deviations of internal parameters, such as steam pressure, drum level and steam temperature, outside safety limits is essential
Keywords :
boilers; parameter estimation; power system simulation; SIMULINK; drum boiler model; drum level; internal parameters deviations assessment; long term power system dynamic simulation; outside safety limits; parameter identification; power output; power system contingency; steam pressure; steam temperature; Analytical models; Boilers; Control system analysis; Integrated circuit modeling; Power generation; Power system dynamics; Power system modeling; Power system protection; Power system simulation; Power system transients;
fLanguage :
English
Journal_Title :
Power Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8950
Type :
jour
DOI :
10.1109/59.744528
Filename :
744528
Link To Document :
بازگشت