DocumentCode :
1473657
Title :
An auto-switch for multisampling of a wire beam electrode corrosion monitoring system
Author :
Eren, Halit ; Lowe, Alexander M. ; Tan, Yong-Jun ; Bailey, Stuart Ian ; Kinsella, Brian
Author_Institution :
Sch. of Electr. & Comput. Eng., Curtin Univ. of Technol., Perth, WA, Australia
Volume :
47
Issue :
5
fYear :
1998
fDate :
10/1/1998 12:00:00 AM
Firstpage :
1096
Lastpage :
1101
Abstract :
An auto-switch device has been designed, constructed, and tested for multisensor corrosion measurements. The auto-switch is able to connect/disconnect the selected wire beam electrode and/or electrode pairs under computer control. A computer controlled analog switch-array consisting of 100 inputs has been used as an essential part of the switch bank. The switch-bank is an essential component of a corrosion-monitoring instrument that is expected to find wide application in industry. The performance of the switch-bank is discussed and its effect on the signals is illustrated
Keywords :
analogue circuits; computerised monitoring; corrosion testing; electric current measurement; electrochemical electrodes; electrochemical sensors; noise; sensor fusion; switches; analog switch-array; auto-switch; computer control; corrosion mapping; corrosion-monitoring instrument; galvanic current; localised corrosion; multisampling; multisensor corrosion measurement; switch-bank; wire beam electrode corrosion monitoring; wire beam electrodes; Corrosion; Current measurement; Electrodes; Galvanizing; Low-frequency noise; Monitoring; Signal analysis; Switches; Voltage; Wire;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/19.746563
Filename :
746563
Link To Document :
بازگشت