DocumentCode :
1473913
Title :
Measurements of harmonic distortion produced by a saturated optical amplifier with a nonlinear microwave network analyzer
Author :
Vael, Philip ; Rolain, Yves ; Barel, Alain R F ; Bliki, Andy
Author_Institution :
Dept. ELEC-VUB, Vrije Univ., Brussels, Belgium
Volume :
47
Issue :
5
fYear :
1998
fDate :
10/1/1998 12:00:00 AM
Firstpage :
1300
Lastpage :
1306
Abstract :
This paper presents a method to measure the harmonic distortion produced by optical amplifiers. Therefore, a recently developed nonlinear-network measurement system has been extended with a laser source and a detector. A proposal for shifting the absolute calibration plane from the electrical to the optical plane is given. The experimental results show that the saturated optical amplifier does not significantly increase the harmonic distortion of the applied modulated optical input signal
Keywords :
S-parameters; calibration; electric distortion measurement; harmonic distortion; microwave reflectometry; network analysers; optical fibre amplifiers; optical saturation; AC power budget; S-parameters; absolute calibration plane; applied modulated optical input signal; harmonic distortion measurement; laser source; linearity test; nonlinear microwave network analyzer; nonlinear optics; nonlinear-network measurement system; optical fiber amplifiers; optical plane; saturated optical amplifier; spectral analysis; Distortion measurement; Harmonic distortion; Laser noise; Optical amplifiers; Optical distortion; Optical modulation; Optical saturation; Proposals; Semiconductor optical amplifiers; Stimulated emission;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/19.746600
Filename :
746600
Link To Document :
بازگشت