DocumentCode :
1474610
Title :
Transient response of controlled rectifier circuits
Author :
Chin, P. T. ; Walter, G. E.
Author_Institution :
General Electric Company Schenectady, N. Y.
Volume :
64
Issue :
4
fYear :
1945
fDate :
4/1/1945 12:00:00 AM
Firstpage :
208
Lastpage :
214
Abstract :
Transients in circuits supplied by controlled rectifiers using gas or mercury-vapor-filled electron tubes are found analytically by an extended superposition method. Loads containing resistance, inductance, and a counter electromotive force are studied, and results are obtained for both rectification and inversion. Examples are based on the half-wave biphase rectifier, while the appendix contains an analysis of a p-phase rectifier. The assumptions include constant-circuit parameters, a fixed firing angle during transients, continuous load current, and no-leakage reactance in the supply transformer.
Keywords :
Electron tubes; Firing; Force; Inductance; Radiation detectors; Rectifiers; Transient analysis;
fLanguage :
English
Journal_Title :
Electrical Engineering
Publisher :
ieee
ISSN :
0095-9197
Type :
jour
DOI :
10.1109/EE.1945.6440977
Filename :
6440977
Link To Document :
بازگشت