Title : 
Adjustment of the 4-port single-junction circulator
         
        
            Author : 
Helszajn, J. ; Buffler, C.R.
         
        
            Author_Institution : 
University of Leeds, Department of Electrical and Electronic Engineering, Leeds, UK
         
        
        
        
        
            fDate : 
6/1/1968 12:00:00 AM
         
        
        
        
            Abstract : 
The 4-port junction circulator differs from the 3-port junction in that the circulation adjustment cannot be reduced to an admittance a t c h i n g procedure. To adjust the 4-port junction circulator requires setting three independent variables. A unique procedure is given for setting the three independent variables one at a time in terms of the scattering coefficients of the junction. The procedure is demonstrated on an experimental waveguide junction.
         
        
        
            Journal_Title : 
Radio and Electronic Engineer
         
        
        
        
        
            DOI : 
10.1049/ree.1968.0053