DocumentCode :
1476438
Title :
Automatic, on-line calibration of flowmeters
Author :
Ridley, P.
Author_Institution :
Serck Controls Limited, Leamington Spa, UK
Volume :
39
Issue :
2
fYear :
1970
fDate :
2/1/1970 12:00:00 AM
Firstpage :
113
Lastpage :
119
Abstract :
This paper describes a method of calibrating digital output flowmeters of the turbine meter type whilst the meters are in use. No interruption of the metering process is involved during calibration. In the specific application for which the system was designed, the volumes of batches of refined petroleum products `shipped¿ in an oil pipeline are metered to an accuracy of 0.05%. Meter calibration cycles are initiated automatically when product types or flow rates change.
Keywords :
engineering applications of computers; flow measurement; fluidics;
fLanguage :
English
Journal_Title :
Radio and Electronic Engineer
Publisher :
iet
ISSN :
0033-7722
Type :
jour
DOI :
10.1049/ree.1970.0017
Filename :
5267710
Link To Document :
بازگشت