DocumentCode :
1478333
Title :
Novel method for real-time monitoring of non-linear transition shift
Author :
Liu, Bo ; Soo, Kian Thiam ; Wood, Roger W.
Author_Institution :
Data Storage Inst., Nat. Univ. of Singapore, Singapore
Volume :
33
Issue :
5
fYear :
1997
fDate :
9/1/1997 12:00:00 AM
Firstpage :
2698
Lastpage :
2700
Abstract :
This paper presents a technique for real-time measurement of non-linear transition shift (NLTS) caused by the adjacent transition. The method is based on the harmonic elimination principle. By measuring the readout amplitude of three selected harmonics from a specific test pattern, the NLTS can be obtained from the amplitudes of the three selected harmonics. The proposed method has the advantage for real-time measurement of the NLTS. This is not true for the existing NLTS measurement techniques. Comparison of the NLTS value measured by the proposed method and the existing method shows satisfactory agreement between them. Furthermore, the proposed method has the advantage of insensitivity to the fluctuation of flying height during the reading and testing process
Keywords :
magnetic recording; magnetic variables measurement; monitoring; real-time systems; NLTS measurement; adjacent transition; flying height fluctuation; harmonic elimination; magnetic recording; nonlinear transition shift; readout amplitude; real-time monitoring; test pattern; Density measurement; Error analysis; Fluctuations; Interference; Magnetic recording; Maximum likelihood detection; Measurement techniques; Memory; Monitoring; Testing; Time measurement;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/20.617449
Filename :
617449
Link To Document :
بازگشت