DocumentCode :
1479826
Title :
Magnetic field and electromagnetic force analysis of 3-phase air-core superconducting power transformer
Author :
Yamaguchi, Hiroshi ; Kataoka, Teruo ; Matsuoka, Hiroki ; Mouri, Tomohide ; Nishikata, Shoji ; Sato, Yukihiko
Author_Institution :
Frontier Technol. Div., Electrotech. Lab., Tsukuba, Japan
Volume :
11
Issue :
1
fYear :
2001
fDate :
3/1/2001 12:00:00 AM
Firstpage :
1490
Lastpage :
1493
Abstract :
The superconducting windings of the air-core superconducting power transformer have possibilities of being exposed to a higher magnetic field than those of the iron-core transformer because of no special paths for magnetic flux. Thus, in this paper, the magnetic field and electromagnetic force acting on the windings of an experimental 3-phase air-core superconducting transformer are analyzed. From the results, it has become clear that the superconducting windings of the air-core transformer are exposed to a 3-dimensional magnetic field containing a rotational component
Keywords :
electromagnetic forces; magnetic fields; magnetic flux; power transformers; superconducting transformers; transformer windings; 3-dimensional magnetic field; 3-phase air-core superconducting power transformer; 3-phase air-core superconducting transformer; electromagnetic force; electromagnetic force analysis; magnetic field; magnetic flux; rotational component; superconducting windings; Electromagnetic analysis; Electromagnetic forces; Magnetic analysis; Magnetic fields; Magnetic flux; Power transformers; Superconducting cables; Superconducting coils; Superconducting transmission lines; Windings;
fLanguage :
English
Journal_Title :
Applied Superconductivity, IEEE Transactions on
Publisher :
ieee
ISSN :
1051-8223
Type :
jour
DOI :
10.1109/77.920057
Filename :
920057
Link To Document :
بازگشت