DocumentCode :
1479869
Title :
Implementation of the CDA procedure in the EMTP
Author :
Lin, Jiming ; Marti, José R.
Author_Institution :
Electr. Power Res. Inst., Beijing, China
Volume :
5
Issue :
2
fYear :
1990
fDate :
5/1/1990 12:00:00 AM
Firstpage :
394
Lastpage :
402
Abstract :
The application of the critical damping adjustment (CDA) technique to some of the main equipment models in the DCG/EPRI version of EMTP is presented. The CDA procedure eliminates the numerical oscillations that can occur in transients simulations that use the trapezoidal rule of integration. The details of this implementation for linear elements, nonlinear reactors, frequency-dependent transmission lines, and synchronous machines are described. Simulation results involving these components are presented, showing the effectiveness of the procedure
Keywords :
damping; electromagnetic fields; power systems; transients; CDA; DCG/EPRI; EMTP; critical damping adjustment; electromagnetic transients program; frequency-dependent transmission lines; linear elements; nonlinear reactors; numerical oscillations; power systems; synchronous machines; transients simulations; Circuits; Damping; Difference equations; Differential equations; EMTP; Frequency dependence; History; Switches; Synchronous machines; Voltage;
fLanguage :
English
Journal_Title :
Power Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8950
Type :
jour
DOI :
10.1109/59.54545
Filename :
54545
Link To Document :