DocumentCode
1480869
Title
Comments on ´Simplification of system model in time domain using continued fraction expansion in third Cauer form´
Author
Aguirre, L.A.
Author_Institution
Dept. of Control Eng., Sheffield Univ., UK
Volume
27
Issue
10
fYear
1991
fDate
5/9/1991 12:00:00 AM
Firstpage
884
Abstract
For original paper see ibid., vol.27, no.5, p.396 (1991). Reduced models obtained by truncating a continued fraction expansion in third Cauer form are, in general, good approximations of the original transient and steady-state responses. This is a consequence of the retention of some Markov parameters and of some time moments of the original model. Although this procedure can only be applied to stable models and does not guarantee the reduced model stability, it is of interest and an algorithm such as the one presented in the original article is of great value. Some mistakes, however, seem to be made.
Keywords
Markov processes; stability; time-domain analysis; transient response; Markov parameters; continued fraction expansion; reduced model stability; stable models; steady-state responses; system model; third Cauer form; time domain; time moments; transient response;
fLanguage
English
Journal_Title
Electronics Letters
Publisher
iet
ISSN
0013-5194
Type
jour
DOI
10.1049/el:19910553
Filename
74977
Link To Document