• DocumentCode
    1485340
  • Title

    A Five-Decade Dynamic-Range Ambient-Light-Independent Calibrated Signed-Spatial-Contrast AER Retina With 0.1-ms Latency and Optional Time-to-First-Spike Mode

  • Author

    Leñero-Bardallo, Juan Antonio ; Serrano-Gotarredona, Teresa ; Linares-Barranco, Bernabé

  • Author_Institution
    Centro Nac. de Microelectron., Consejo Super. de Investig. Cientificas, Sevilla, Spain
  • Volume
    57
  • Issue
    10
  • fYear
    2010
  • Firstpage
    2632
  • Lastpage
    2643
  • Abstract
    Address Event Representation (AER) is an emergent technology for assembling modular multiblock bio-inspired sensory and processing systems. Visual sensors (retinae) are among the first AER modules to be reported since the introduction of the technology. Spatial-contrast AER retinae are of special interest since they provide highly compressed data flow without reducing the relevant information required for performing recognition. The reported AER contrast retinae perform a contrast computation based on the ratio between a pixel´s local light intensity and a spatially weighted average of its neighborhood. This resulted in compact circuits but with the penalty of all pixels generating output signals even if they sensed no contrast. In this paper, we present a spatial-contrast retina with a signed output: Contrast is computed as the relative difference (not the ratio) between a pixel´s local light and its surrounding spatial average and normalized with respect to ambient light. As a result, contrast is ambient light independent, includes a sign, and the output will be zero if there is no contrast. Furthermore, an adjustable thresholding mechanism has been included, such that pixels remain silent until they sense an absolute contrast above the adjustable threshold. The pixel contrast-computation circuit is based on Boahen´s biharmonic operator contrast circuit, which has been improved to include mismatch calibration and adaptive-current-based biasing. As a result, the contrast-computation circuit shows much less mismatch, is almost insensitive to ambient light illumination, and biasing is much less critical than in the original voltage biasing scheme. The retina includes an optional global reset mechanism for operation in ambient-light-independent Time-to-First-Spike contrast-computation mode. A 32 32 pixel test prototype has been fabricated in 0.35-m CMOS. Experimental results are provided.
  • Keywords
    calibration; image recognition; image representation; image sensors; AER; Boahen biharmonic operator; adaptive-current based biasing; address event representation; adjustable thresholding mechanism; ambient light illumination; image recognition; mismatch calibration; pixel local light; spatial-contrast retina; time 0.1 ms; time-to-first-spike mode; visual sensors; Assembly systems; Biosensors; Calibration; Circuits; Delay; Lighting; Retina; Signal generators; Testing; Voltage; Address-event-representation; analog circuits; artificial retina; bio-inspired circuits; calibration; contrast sensors; image sensors; low power circuits; spiking circuits; transistor mismatch;
  • fLanguage
    English
  • Journal_Title
    Circuits and Systems I: Regular Papers, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1549-8328
  • Type

    jour

  • DOI
    10.1109/TCSI.2010.2046971
  • Filename
    5460900