• DocumentCode
    1485616
  • Title

    Internal corona spaces in cables

  • Author

    Kitchin, D. W. ; Pratt, O. S.

  • Author_Institution
    Simplex Wire & Cable Company, Cambridge, Mass.
  • Volume
    76
  • Issue
    11
  • fYear
    1957
  • Firstpage
    989
  • Lastpage
    989
  • Abstract
    IN THE DEVELOPMENT of high-voltage cables insulated with thermoplastics or rubber, it is necessary to measure the corona onset voltage. The manometric method detects internal corona by the decrease in air pressure caused by absorption of corona-activated oxygen. The rate of pressure drop increases rapidly with voltage. By connecting a capillary oil manometer to the sample, this pressure drop can be measured. In this study, all voltages are 60 cycles rms.
  • Keywords
    Absorption; Cable shielding; Conductors; Corona; Dielectrics; Polyethylene; Silver;
  • fLanguage
    English
  • Journal_Title
    Electrical Engineering
  • Publisher
    ieee
  • ISSN
    0095-9197
  • Type

    jour

  • DOI
    10.1109/EE.1957.6442814
  • Filename
    6442814