• DocumentCode
    1485855
  • Title

    Comparison of Block Matching and Differential Methods for Motion Analysis of the Carotid Artery Wall From Ultrasound Images

  • Author

    Golemati, S. ; Stoitsis, J.S. ; Gastounioti, A. ; Dimopoulos, A.C. ; Koropouli, V. ; Nikita, K.S.

  • Author_Institution
    First Intensive Care Unit, Nat. & Kapodistrian Univ. of Athens, Athens, Greece
  • Volume
    16
  • Issue
    5
  • fYear
    2012
  • Firstpage
    852
  • Lastpage
    858
  • Abstract
    Motion of the carotid artery wall is important for the quantification of arterial elasticity and contractility and can be estimated with a number of techniques. In this paper, a framework for quantitative evaluation of motion analysis techniques from B-mode ultrasound images is introduced. Six synthetic sequences were produced using 1) a real image corrupted by Gaussian and speckle noise of 25 and 15 dB, and 2) the ultrasound simulation package Field II. In both cases, a mathematical model was used, which simulated the motion of the arterial wall layers and the surrounding tissue, in the radial and longitudinal directions. The performance of four techniques, namely optical flow (OFHS), weighted least-squares optical flow (OFLK(WLS)), block matching (BM), and affine block motion model (ABMM), was investigated in the context of this framework. The average warping indices were lowest for OFLK(WLS) (1.75 pixels), slightly higher for ABMM (2.01 pixels), and highest for BM (6.57 pixels) and OFHS (11.57 pixels). Due to its superior performance, OFLK(WLS) was used to quantify motion of selected regions of the arterial wall in real ultrasound image sequences of the carotid artery. Preliminary results indicate that OFLK(WLS) is promising, because it efficiently quantified radial, longitudinal, and shear strains in healthy adults and diseased subjects.
  • Keywords
    Gaussian noise; biomedical ultrasonics; blood vessels; image matching; image motion analysis; image sequences; medical image processing; B-mode ultrasound images; Gaussian noise; affine block motion model; arterial elasticity; arterial wall layers; block matching; carotid artery wall; contractility; differential methods; diseased subjects; healthy adults; mathematical model; motion analysis; noise figure 15 dB; noise figure 25 dB; quantification; speckle noise; synthetic sequences; ultrasound simulation package Field II; weighted least-squares optical flow; Carotid arteries; Image sequences; Indexes; Mathematical model; Strain; Ultrasonic imaging; Block matching (BM); carotid; motion analysis; optical flow (OF); ultrasound; Adult; Aged; Aged, 80 and over; Carotid Arteries; Carotid Stenosis; Humans; Image Processing, Computer-Assisted; Middle Aged; Movement; Phantoms, Imaging; Vascular Stiffness;
  • fLanguage
    English
  • Journal_Title
    Information Technology in Biomedicine, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1089-7771
  • Type

    jour

  • DOI
    10.1109/TITB.2012.2193411
  • Filename
    6178798