• DocumentCode
    1486959
  • Title

    Eddy current losses and unbalance in electrode arms

  • Author

    Cao, M. ; Biringer, P.P. ; Bulat, V.

  • Author_Institution
    Dept. of Electr. Eng., Toronto Univ., Ont., Canada
  • Volume
    24
  • Issue
    6
  • fYear
    1988
  • fDate
    11/1/1988 12:00:00 AM
  • Firstpage
    2670
  • Lastpage
    2672
  • Abstract
    The various parameters influencing the eddy-current losses and unbalance in electrode arms of an arc furnace are investigated. The volume integral equation method is used. Current distribution, phase impedance, bus-voltage drop, and power loss are presented for various bus positions and arm configurations. Experiments conducted in the laboratory have confirmed the calculations
  • Keywords
    arc furnaces; current distribution; eddy current losses; integral equations; arc furnace; arm configurations; bus positions; bus-voltage drop; current distribution; eddy-current losses; electrode arms unbalance; phase impedance; power loss; volume integral equation method; Arm; Circuits; Conductors; Current density; Current distribution; Eddy currents; Electrodes; Equations; Proximity effect; Voltage;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.92208
  • Filename
    92208